Hi all- We have an opening for an echo tech in our hospital. It is a large childrens hospital in Wisconsin(Milwaukee). The hospital is connected to a medical...
Hello group! We are looking for a few bottles of Optison for animal studies. Would love to take your donation or buy it. Thank you. Anatoly Broyde San Diego...
Dear group: I work in a private full service office in San Francisco. Our predominate ultraound machine was a Ge ViVid 4. Since we want to expand our...
... Sonosite Titan is a fine portable machine. Joshua Warren Birmingham,Al ... platforms for pediatric echo. In the past portable platforms were incomplete...
I've seen a few of these in the past couple of years. The place I work at now has an HP Sonos5500 with the most recent software update. As backwards and left...
Does anyone use the Philips IE33 machine? What are your feelings about it, compared to the Philips 5500? Thanks!...
Jessica Freiwald
jessfreiwald@...
Feb 6, 2006 2:11 pm
8167
Craig: I think that the vivid 1 es the best acho machine, but is very expensive , now the micromaxx is new machine of sonosite look nice , the cypress is a...
I think the IE33 is a really good machine.It shows the endocardium borders very well.The only problem I can see with it is there are a few bugs that hasn't...
I use both machines in HUMC in NJ and MSKCC in NYC. The difference is, imaging with the ie33 is crystal clear. Even with COPD or obesity, you just get great...
Jess, I sell both of these systems. Here is the lowdown. Most sonographers agree that the 5500 platform is much more user friendly than the IE 33. However...
Hello Jessica, I worked with de Sonos 5500 and now we have two IE33 machines. Better: image quality, transducer technology, ergonomics, the Monitor, easy to...
I have just finished my Echo clinical rotation this past Friday. First thing that morning, I walked into the chief of cardiologists office and handed him my...
What I look for when interviewing a candidate and reviewing cases is: Did they answer the clinically relevant question(s) that the echocardiogram was meant to...
2 words.... HATE IT ... From: Jessica Freiwald <jessfreiwald@...> To: echocardiography@yahoogroups.com Sent: Sat, 04 Feb 2006 09:27:25 -0500 Subject:...
I will share mine. I went to interview and all was going well, I was introduced to the lead physician in the practice and he took me to show me around the...
I have an embarrassing story to tell about my first day... I was new, and slow, and kind of clueless. The pace in the lab was very fast. Each tech was expected...
... on ... last ... interview. ... Don't be too hard on yourself. Don't set yourself up to fail by telling prospective employers you are anything more then a...
Of course any first interview is extremely nerve racking and pressurized but you may have to prove yourself several times before getting a position. Just don't...
katie bittner
rdcs1959@...
Feb 8, 2006 5:39 pm
8179
Hello everyone, I've been doing Adult Echo for 5 years now and looking to explore other avenues. I'm actually quite interested in learning Fetal Echo. Can...
I just finished my clinicals this past summer. I lucked out because the hospital I interviewed at knew my professor from school so my interview wasn't too bad...
It is false tendon - benign entity Kannan ... -- Dr.D.Kannan - Cardiologist Sankar Institute of Medical Science Kollam - 691001 , Kerala , India Home...
Jessica, We have had the IE33 for one month. I really like the image quality,the 2D is the best I have seen. I have been scanning for over 10 years and am...
With the latest upgrade and an S3 transducer, the 5500 is still an excellent machine. It simply doesn't have the online capabilities that are really required...
Hi 1. Text Book of Fetal Cardiology 2. Atlas of Fetal Cardiology 3. Atlas of Fetal Echocardiography 4. Fetal Echocardiography All by Lindsay Allan are the best...
No, this is all about timing. After the transducer element shouts out a beam, it shuts up and listens for the returning sound. The longer it waits, the deeper...
It doesn't affect the actual velocity. It affects the system's ability to measure velocity without aliasing. This is the PRF/Nyquist Limit thing. To measure...
Pulsed Wave (PW) Doppler as well as Color Flow Doppler (which is a variant of PW Doppler) has a sample rate, known as the pulse repetition rate or PRF that is...