Search the web
Sign In
New User? Sign Up
echocardiography
? Already a member? Sign in to Yahoo!

Yahoo! Groups Tips

Did you know...
Hear how Yahoo! Groups has changed the lives of others. Take me there.

Best of Y! Groups

   Check them out and nominate your group.

Messages

  Messages Help
Advanced
Messages 5544 - 5573 of 11156   Oldest  |  < Older  |  Newer >  |  Newest
Messages: Simplify | Expand   (Group by Topic) Author Sort by Date ^
5544
Nowadays we are using contrast to see better the endocardium, to improve the doppler signal and to study myocardium perfusion. WQPereira ECOR Rio de Janeiro ...
Wanderley Quarte Pere...
wqp@...
Send Email
Mar 2, 2004
2:01 pm
5545
Did you try a ped-off probe? Many times on those patients that small probe is very useful....
simplel@...
Send Email
Mar 2, 2004
2:01 pm
5546
Hello, Is using contrast can lead to the overestimation of AoV "stenitic jet" velocity? Another way to ask this question: is V1/V2 ratio going to change...
a bro
abro15
Offline Send Email
Mar 2, 2004
2:01 pm
5547
many times you can get a great sub costal shoert axis on these patients as well or Doppler the mitral val sub costal...
simplel@...
Send Email
Mar 2, 2004
2:02 pm
5548
Hi, Sylvia. We just had our first day of Bi-ventricular pacemaker optimization. We did 8 patients. The Medtronic Rep, our pacemaker nurse and our echo staff...
Nanci McFarland
nnaneko7
Offline Send Email
Mar 2, 2004
2:03 pm
5549
Hi Nikki i 100% agree with you on the subject. with increasing life expectancy , we are having a lot more geriatric patients and with a lot of anomalies...
harry bedi
harry_echotech
Offline Send Email
Mar 2, 2004
2:03 pm
5550
Pam, I have recently begun rolling patients with poor windows and obese patients onto their RIGHT side to obtain a better window . Believe it or not, this...
cdecho0510
Offline Send Email
Mar 2, 2004
2:04 pm
5551
Until ASE issues its "Standards" on performing Doppler with pharmaceutical contrast agent, I would stay away from using both at the same time....
akory99@...
realakory99
Offline Send Email
Mar 2, 2004
2:04 pm
5552
I was really pleased with the various responses I received for my question RE: Cardiomyopathy. You have provided me with alot of interesting ideas to pursue....
cdecho0510
Offline Send Email
Mar 2, 2004
2:06 pm
5553
Parcial Anomalous Pulmonary Venus Return ,un wich one or more Pulmonary Veins drains into the RA or SVC could be a cause for enlargement of RA, however yuor...
Hector Trungelliti
atrungell@...
Send Email
Mar 2, 2004
2:06 pm
5554
can any body tell me please does all machin can performe tissue doppler imaging? esmail James Bergfeld <bergfelj@...> wrote: Anne, I measure E, A, DT,...
esmail chakra
ecchakra
Offline Send Email
Mar 2, 2004
2:06 pm
5555
... pacemaker clinic. ... but lacking echo ... me? ... Dear Sylvia: I worked part time in a large CV clinic over the past 18 months, where we participated with...
aruredytoo
Offline Send Email
Mar 2, 2004
2:06 pm
5556
Contrast can certainly help to bring out the weaker Doppler signals. Just be aware, the current 2nd generation contrast agents are only approved for LV...
Elton Aguilar
eltonaa@...
Send Email
Mar 2, 2004
2:06 pm
5557
I want to thank everyone for your wonderful replies to my post. I have moved on from this "incident" and taken it as a learning experience. It's not easy...
Pam
Pamster73
Offline Send Email
Mar 2, 2004
2:10 pm
5558
Dear lv4everis, Thank you, your help and opinion was very valuable. It does not matter that you're a student. Actually, sometimes it's even better since your...
Abello4@...
Send Email
Mar 2, 2004
5:10 pm
5559
Dear Akory 99, I would aprreciate you normal values and their references thank you!! Anne...
Abello4@...
Send Email
Mar 2, 2004
5:11 pm
5560
Sylvia, Dr. Marcus and I have have been doing pacemaker optimization in patients with dilated cardiomyopathy for some nine year at The Iowa Heart Center....
Mark Harry
mjhcuc
Offline Send Email
Mar 2, 2004
5:12 pm
5561
Thankyou Michael for your response to the physcis exam; I myself took the Adult echo approx. a year ago. Eldemens Course will also help with this task. My...
Brenda King
bkboiler40
Offline Send Email
Mar 2, 2004
5:13 pm
5562
Dear frieds, dealing with normal abdominal aorta diameters we did our own modest investigacion calling and inviting individuals 60 years ald or older to have...
hector lardani
lardanih@...
Send Email
Mar 2, 2004
10:09 pm
5563
Wait until you see an 8cm LA with a clot at the apex of the LV, 33yo female, no fun at all. All we can really do is endure and try to learn from each ...
JLCJR55@...
Send Email
Mar 2, 2004
11:19 pm
5564
Remember that the outlines available on the ARDMS site include the percentage of questions which will be asked for each topic on the outline. Some questions ...
Gerson Lichtenberg
gersonsl@...
Send Email
Mar 3, 2004
4:19 pm
5565
Dear Esmel, Not every machine can do tissue doppler. it has to have the software. Anne...
Abello4@...
Send Email
Mar 3, 2004
4:19 pm
5566
Greater Lafayette Health Services in Lafayette, IN has one immediate opening for a Vascular/Echo Tech. Another opening as a Echo Tech opening up in June 2004....
keelee.page@...
Send Email
Mar 3, 2004
4:22 pm
5567
Hi Ms. Pam, In India we see Mitral stenosis every day of the echo. They are of various types and sizes. If you want more details of MS, look into some...
Dr.Sahasranam
kvsnam
Offline Send Email
Mar 3, 2004
4:22 pm
5568
I do believe if reject, scale and optimizing 2d image are all done properly that most machines can get a good tissue doppler pattern at the septal side of the...
Gerald Hinderliter
Gerald.Hinderliter@...
Send Email
Mar 3, 2004
5:05 pm
5569
Dear Group, I would like to add another job opening to the list. This is for a Pediatric Echo job at the University of Iowa Hospital and Clinc. This position...
Marika Klesic
mrklessic@...
Send Email
Mar 3, 2004
5:06 pm
5570
TDI is one setting that MUST be uniform across the board. Without ASE standards and Manufacturers settings, how would we know that the measurement we get is...
akory99@...
realakory99
Offline Send Email
Mar 3, 2004
10:44 pm
5571
Just a thought..... You may also want to become adept at obtaining a good Doppler pattern from the lateral side, especially if the patient has a significant...
Thomas M. Kehoe
tksm@...
Send Email
Mar 3, 2004
10:44 pm
5572
Tissue doppler has to do with the machine settings. You can do tissue doppler on any machine. Before we purchased machines with the tissue doppler package we...
Laffey, Dawn
Laffey.Dawn@...
Send Email
Mar 3, 2004
10:47 pm
5573
Interesting...I measure from the lateral side of the MV ring in a 4C image. Is there a preferred/validated position to measure from? Chris Brown Shetland UK ...
Brown, Chris
Chris.Brown@...
Send Email
Mar 4, 2004
2:51 pm
Messages 5544 - 5573 of 11156   Oldest  |  < Older  |  Newer >  |  Newest