4797
There are several job openings posted on the website - echocareers.com. Good Luck...
eckotek@...
deechotek
Offline Send Email
Sep 1, 2003
2:36 pm
4798
i am in puebla mexico of course i am interested in echocardiography i have worked in this area for about four years and i will like to know more about this...
DR.ROBERTOV VARGAS EN...
soncoy
Offline Send Email
Sep 1, 2003
2:37 pm
4799
Dehydrated Patients may commonly present with low volumes and occasionally mid cavitary gradients. ... From: <echocardiography@yahoogroups.com> To:...
Kelly
echocanyons
Offline Send Email
Sep 1, 2003
2:37 pm
4800
Dear friends, Does anybody know one can download clip files from a Accuson Sequoia without a dedicated workstation? Thanks, Gad Keren...
Gad Keren
kereng@...
Send Email
Sep 1, 2003
2:38 pm
4801
Hi, I have been trying to cal. the RV pressures and Thought there was a formula for using the pul. Insufficiency and the TR pg. I know if I use the TR pg and...
mlouw44@...
Send Email
Sep 1, 2003
2:39 pm
4802
dear Wayne Moore : I will be happy to get any collor doppler mashine whith which i will be able to see the children,on My contry,beaocosse we stil se the...
Bardhil Idrizi
bardhilidrizi
Offline Send Email
Sep 1, 2003
2:39 pm
4803
http://groups.yahoo.com/group/Medical_Coders/join...
Christine Goans
cmgoans
Offline Send Email
Sep 1, 2003
2:53 pm
4804
Dear Keren You can't download Acuson files without a workstation, but you can do one of two things to download images, if you have an MO reader you can save...
Enrique Pantin
pantin@...
Send Email
Sep 2, 2003
4:27 pm
4805
You can clip store or image store on your Sequoia, then transfer the information on to a MO disc. If you have a computer with a magneto-optical drive, you can...
Nanci McFarland
nnaneko7
Offline Send Email
Sep 2, 2003
4:27 pm
4806
Mary Lou, PI allows you to estimate PA end-diastolic pressure (which is the same as pulmonary wedge pressure): PAEDP = PWP = 4 x (PI end-diastolic velocity ²)...
akory99@...
realakory99
Offline Send Email
Sep 2, 2003
4:27 pm
4807
Yes you can but you would need a MOD drive on a PC to transfer it and a DICOM reader to read it such as access point or showcase or there are others. As for...
Kelly
echocanyons
Offline Send Email
Sep 2, 2003
4:27 pm
4808
I hoping for one ATL UM9 with pediatric cardiology(phased arrey 3,5-5 mhz) probe and one linear 5 or 7,5 mhz Wayne Moore <gwm@...> wrote:What type of...
Bardhil Idrizi
bardhilidrizi
Offline Send Email
Sep 2, 2003
4:27 pm
4809
The end dias PI PG(usually presents as a doppler shelf in normal to mild PI) would reflect the end dias Pressure in the RV The sys TR PIG would represent the...
Kelly
echocanyons
Offline Send Email
Sep 2, 2003
4:27 pm
4810
Does anyone out there know where I might find population study information on normal LA and LV size in adults? Mark Harry RDCS ... This electronic message may...
Mark Harry (IHC-Laurel)
mharry@...
Send Email
Sep 2, 2003
5:28 pm
4811
Does anyone know numbers of LA Volumes?? We use anything above 48 ml is enlarged but we dont have the numbers to classify them into categories In terms of: ...
Jess
jammers197997
Offline Send Email
Sep 3, 2003
4:03 pm
4812
hi Could you please give me an explanation about transvalvular gradient in terms of prosthetic valves. i was studying prosthetic valves here and the book says...
abyjohn25
Online Now Send Email
Sep 3, 2003
5:06 pm
4813
I am looking for reference material on normal LA and LV size in adults. ... From: Jess [mailto:jess@...] Sent: Tuesday, September 02, 2003 4:19 PM ...
Mark Harry (IHC-Laurel)
mharry@...
Send Email
Sep 3, 2003
5:40 pm
4814
We don't have documentation as to where this information came from, but our cardiologist use the following: Mild LAE ------ 4.1 cm to 4.8 cm Mod LAE -----...
RTURNER33@...
Send Email
Sep 3, 2003
5:40 pm
4815
Kelly is correct you will need a dicom viewer and a 3.5 MO drive. You can get a trial version of AccessPoint on our Web site at www.freelandsystems.com if you...
Derek Strauch
derek_ms
Offline Send Email
Sep 3, 2003
5:40 pm
4816
Can you rely on Doppler measurements for valve gradient or area quantification? Here's an interesting pair of CW Doppler images taken on the same patient, with...
Bill Phillips
phillipsbill@...
Send Email
Sep 4, 2003
2:41 pm
4817
The reason for a gradient on a normal prothetic vavle is that the prothetic orifice is smaller then what the native valve would have been. ... hi Could you...
Gerald Hinderliter
Gerald.Hinderliter@...
Send Email
Sep 4, 2003
2:43 pm
4818
Dtsch Med Wochenschr. 1985 Jan 25;110(4):123-8. [Normal values for two-dimensional echocardiography] [Article in German] Erbel R, Henkel B, Ostlander C, Clas...
Dr. Jamil Mattar Vale...
jamil@...
Send Email
Sep 4, 2003
2:44 pm
4819
here at my hospital we have a nova microsonics image view dcr echo image analysis system availible for sale. if any group members are interested in it please...
scot mackeil
jscot2524
Offline Send Email
Sep 4, 2003
2:44 pm
4820
Is it essential to use CW when measuring the pressure half-time of a stenotic mitral valve if the velocity is within the alias limit of PW? Also, how reliable...
justinpadams
Offline Send Email
Sep 4, 2003
2:45 pm
4821
Aby, all this means is that prosthetic valves, especially in the aortic position, will have a mild, and maybe moderate pressure gradient. The problem with...
Elton Aguilar
eltonaa@...
Send Email
Sep 4, 2003
2:45 pm
4822
To answer this question, think in terms of low blood volume. You may see: 1. Very small or collapsed IVC. 2. LV chamber size may be small and systolic function...
Elton Aguilar
eltonaa@...
Send Email
Sep 4, 2003
2:47 pm
4823
Boat anchor!...
WHITEDAVEL@...
Send Email
Sep 5, 2003
12:43 pm
4824
On a similar topic, I've had a physician ask me about an indexed LA diameter, based on the BSA. I've not found anything on that. Does anyone else use this...
KEVIN MARSHALL
k1d1m1
Offline Send Email
Sep 5, 2003
12:43 pm
4825
Aby, Compared with native valves, all prosthetic valves are mildly stenotic, maybe with the exception of an allograft (e.g., homograft.) This is due to the...
G M
MillerGregoryS
Offline Send Email
Sep 5, 2003
12:44 pm
4826
I found the article by Ilercil et al. very useful. They indexed LV size to sex and height, but upper limits of LA size was reported as 3.8 cm for women and 4.1...
jean yacoub
jyacoub@...
Send Email
Sep 5, 2003
12:51 pm
Messages 4797 - 4826 of 11168   Oldest  |  < Older  |  Newer >  |  Newest